<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Disaster Prevention and Management Knowledge</title>
<title_fa>دانش پیشگیری و مدیریت بحران</title_fa>
<short_title>Disaster Prev. Manag. Know.</short_title>
<subject>Literature &amp; Humanities</subject>
<web_url>http://dpmk.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-5955</journal_id_issn>
<journal_id_issn_online>2538-1814</journal_id_issn_online>
<journal_id_pii>0</journal_id_pii>
<journal_id_doi>10.32598</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>0</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>64793</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2026</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ملاحظاتی در طراحی لرزه‌ای اجزای غیرسازه‌ای حساس به شتاب در سازه‌های کوتاه و میان‌مرتبه قاب خمشی فولادی در حوزه نزدیک گسل</title_fa>
	<title>Seismic Design Considerations for Acceleration-sensitive Non-structural Components</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;زمینه و هدف&lt;/strong&gt; یکی از موارد حائز اهمیت در کاهش تلفات و صدمات انسانی و اقتصادی در شهرهای لرزه&#8204;خیز، امکان&#8204;پذیری و تداوم بهره&#8204;برداری و خدمات&#8204;رسانی ساختمان&#8204;های با کاربری&#8204;های مهم بعد از زلزله&#8204;های محتمل &#8204;می&#8204;باشد که برای این منظور، حفظ و تأمین عملکرد اجزای غیرسازه&#8204;ای منصوب در ساختمان و جلوگیری از آسیب، سقوط و فروریزش این اجزاء علاوه&#8204;بر حفظ عملکرد مناسب اجزای سازه&#8204;ای ضروری &#8204;می&#8204;باشد.&lt;br&gt;
&lt;strong&gt;روش: &lt;/strong&gt;در این پژوهش، با لحاظ نمودن اثر هم&#8204;زمان مؤلفه افقی و قائم 2 دسته 11 عددی از شتابنگاشت&#8204;های حوزه دور و نزدیک گسل، به بررسی نیروی اینرسی وارده به جزء غیرسازه&#8204;ای با در نظر گرفتن محل نصب آن در طبقات مختلف ساختمان پرداخته شده است. دو نمونه سازه فولادی منظم با سیستم باربر جانبی قاب خمشی با شکل&#8204;پذیری متوسط در دو ارتفاع 4 و 8 طبقه واقع در ساختگاه خاک سخت تحت اثر تحلیل تاریخچه زمانی غیرخطی قرار گرفته است. گستره اجزای غیرسازه&#8204;ای حساس به شتاب در این تحقیق، شامل کلیه اجزای متصل به یکی از کف&#8204;ها یا سقف&#8204;های سازه&#8204;ای با زمان تناوب&#8204;های کمتر از 0/5 ثانیه &#8204;می&#8204;باشد که از شتاب ایجادشده در دیافراگم مربوطه تأثیر &#8204;می&#8204;پذیرند. دو زیرگروه از اجزای غیرسازه&#8204;ای شامل سقف کاذب و برج خنک&#8204;کننده چیلر به&#8204;عنوان نمونه موردی با مدل یک درجه آزادی بررسی شده است.&lt;br&gt;
&lt;strong&gt;یافته ها&lt;/strong&gt; با بررسی اثرات حوزه نزدیک گسل بر سازه&#8204;های موردمطالعه، به&#8204;ترتیب افزایش تا سقف 19 درصد و تا سقف 10 درصد در نیروی اینرسی افقی و عمودی وارده به مرکز جرم اجزای غیرسازه&#8204;ای واقع در طبقات مختلف به&#8204;خصوص در طبقات نزدیک بام مشاهده شده است. اثرات افزایشی مذکور در سازه کوتاه&#8204;مرتبه نسبت به سازه میان&#8204;مرتبه بارزتر بوده است که &#8204;می&#8204;تواند ناشی از نزدیک بودن زمان تناوب کوتاه اجزای غیرسازه&#8204;ای به فرکانس طبیعی سازه کوتاه&#8204;مرتبه و محتوای فرکانسی رکوردهای نزدیک گسل باشد.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;نتیجه گیری&lt;/strong&gt; نتایج بررسی ضریب بزرگ&#8204;نمایی شتاب راستای قائم در مرکز جرم اجزای غیرسازه&#8204;ای نشان داد توجه به زمان تناوب مد عمودی این اجزاء در طراحی لرزه&#8204;ای آن&#8204;ها ضرورت دارد؛برای نمونه، متوسط ضریب مذکور برای یکی از انواع برج خنک&#8204;کننده با زمان تناوب مد قائم 0/22 ثانیه، منصوب&#8204;شده بر روی بام سازه&#8204;های موردمطالعه به مقادیری بین 2 تا 3 برابر مقدار الزام&#8204;شده آیین&#8204;نامه&#8204;ای نزدیک شده است.&#8204;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;Background and objective&lt;/strong&gt; One of the key factors in reducing human and economic losses in earthquake-prone cities is ensuring the operability and continuity of service of buildings with critical functions after probable earthquakes. To achieve this, it is essential not only to maintain the proper performance of structural components but also to preserve and guarantee the functionality of non-structural components installed within the building, preventing their damage, collapse, or detachment.&lt;br&gt;
&lt;strong&gt;Method &lt;/strong&gt;This study investigated the acceleration amplification factor and the resulting inertial forces on non-structural components, considering their installation locations along the building height. Two regular steel structures, each with a lateral load-bearing system consisting of a medium-ductility flexural frame at heights of 4 and 8 stories, located on a hard soil site, were subjected to nonlinear time-history analysis. The range of acceleration-sensitive non-structural components included all elements connected to a structural floor or ceiling with a natural period of less than 0.5 seconds, influenced by the acceleration generated in the corresponding diaphragm. Two subcategories of non-structural components&amp;mdash;suspended ceilings and chiller cooling towers&amp;mdash;were examined as case studies using single-degree-of-freedom (SDOF) modeling.&lt;br&gt;
&lt;strong&gt;Results &lt;/strong&gt;By examining the effects of the near-fault zone on the studied structures, increases of up to 19% and up to 10% were observed in the horizontal and vertical inertial forces, respectively, applied to the center of mass of non-structural components located on different floors&amp;mdash;especially on floors near the roof. These additive effects were more pronounced in the short-rise structure than in the medium-rise structure, which may be attributed to the closeness of the short period of the non-structural components to the natural frequency of the short-rise structure and the frequency content of the near-fault records.&lt;br&gt;
&lt;strong&gt;Conclusion &lt;/strong&gt;The vertical acceleration magnification factor at the center of mass of non-structural components indicates the necessity of considering the period of the vertical mode of these components in their seismic design. For example, the average magnification factor for one type of cooling tower, with a vertical mode period of 0.22 seconds installed on the roof of the studied structures, approached values between two and three times those required by current regulations.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>اجزای غیرسازه‌ای, حوزه نزدیک گسل, ضریب بزرگ‌نمایی (تشدید) شتاب, نیروی اینرسی</keyword_fa>
	<keyword>Non-structural components, Near-fault earthquakes, Acceleration amplification factor, Inertia force</keyword>
	<start_page>36</start_page>
	<end_page>61</end_page>
	<web_url>http://dpmk.ir/browse.php?a_code=A-10-210-4&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mahboobeh</first_name>
	<middle_name></middle_name>
	<last_name>Pirizadeh</last_name>
	<suffix></suffix>
	<first_name_fa>محبوبه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پیری زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>pirizadeh@iau.ac.ir</email>
	<code>10031947532846008568</code>
	<orcid>10031947532846008568</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Civil Engineering, WT.C., Islamic Azad University, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی عمران، واحد تهران غرب، دانشگاه آزاد اسلامی، تهران، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
